Reuben Saltzman

Photos From New Construction Inspections

If you’re buying a new construction home, get it inspected by a private home inspector.

I could wax on and on about how important home inspections are for new construction, especially if the builder tells you that a private home inspection isn’t necessary, but I’ve found that photos are far more convincing than anything I could say.  I took all of the photos below at homes in Minnesota that were either new construction or only a couple years old; the issues that you’re seeing are all ‘original’ issues; they weren’t created after the homes passed their final inspections by the city.

Click on any of the photos for a larger version.

Roofs

The first thing that I typically inspect is the roof lines – I start doing this as I drive up to a house.  When valleys dump next to a wall, or even worse, in to the back side of brick veneer siding, you’re asking for trouble.  These roofs are designed to fail.

Roof lines 2

Roof lines 3

Roof lines 41

Roof lines 1

I took the photo above at a house that was almost ten years old.  Thankfully there was a small portion of unfinished basement where I was able to pull the fiberglass insulation away from the rim space to confirm my suspicions; this had been leaking for a long time.  I really wanted to know what it looked like behind the siding… but my home inspections aren’t invasive or destructive so I couldn’t get all ‘Mike Holmes’ on them.

Roof lines damage

Decks

I’ve written several blogs about deck construction defects, but unfortunately handy homeowners and weekend warriors don’t have the market cornered when it comes to shoddy workmanship.  Yes, I find plenty of deck defects even on new construction.

The most common deck defect that I find is improper nails used on joist hangers.  The nail I’m holding in the photo below isn’t even half as long as it should be.  I seem to find this defect at just about every other deck inspection.

Decks - joist hanger nails

When special / non-standard joist hangers are needed, there’s about a 20% chance that the installer will use whatever happens to be in their truck.  In other words, this is usually done right, but I still find a lot that are done wrong.  The joist hangers shown below were the wrong ones for the job and won’t hold what they’re supposed to.

Decks - joist hangers 2

Decks - joist hangers

Stairway stringers seem to be a hard thing to cut.

Decks - Steps

Deck stairways aren’t difficult to attach properly, but some people sure make it look difficult.  Those long metal straps shown below are certainly not holding this stairway up.

Decks - Steps2

In the next two photos, the deck stairway is attached to a piece of siding trim with deck screws. This is ridiculously wrong.  Yikes.

Decks - steps3

Decks - steps31

Electrical

I don’t find a lot of electrical defects on new houses, but I do find them.  In the next two photos below, there are double tapped circuit breakers and double tapped neutral wires.  These breakers aren’t designed to be double tapped, and neutral wires are never allowed to be double tapped.  I honestly think the electrical inspectors never even looked inside these panels, because these are blatant violations.  By the way, these weren’t at the same properties.

Electrical - double tapped breakers

Electrical - double tapped neutrals

This next violation was more comical than anything else; it’s no big deal, but someone obviously missed a day of training.

Electrical - wrong low voltage tap

Plumbing

There are two common defects that I find on new construction houses all the time – one is test plugs or test caps still in place at the plumbing vents.  Test caps need to be installed at plumbing vents so the drain, waste and vent system can be pressure tested.  After the pressure test is done, someone needs to get up on the roof and get rid of the caps or plugs, but this is often forgotten about.  This effectively disables the vents.

Plumbing - knockout in place

The other plumbing issue that I find all the time with new construction houses is missing access panels for bath tubs.  Either there is just no access provided, or someone installs a panel but never puts a hole in the wall.  I always chuckle when I remove an access panel and there is nothing behind it… but I’m no longer surprised.

Plumbing - missing access panel

HVAC

I find a lot of the same HVAC installation defects over and over.  In the photo below, the AC units should have been at least 24″ from each other.  Let me remind you… this is new construction, and these installations have already passed the city inspections.

HVAC - AC units too close

Venting for high efficiency furnaces gets installed improperly all the time.  I often find installation manuals that have never been opened.  In the photo below, the vent terminals for the furnace were installed wrong; the diagram below the photo came right out of the installation manual.

HVAC - wrong vent terminals
HVAC - wrong vent terminals 2

Any time the vent passes through an unconditioned space, it needs to be insulated.  This doesn’t always happen.  By the way, I read installation manuals.

HVAC - missing insulation on vent

HVAC - missing insulation on vent 2

Powervent water heaters have a huge list of things on the outside of the house that they can’t terminate too close to; in the photo below, the vent terminates way too close to the gas meter.

HVAC - wrong vent terminal 3
HVAC - water heater vent terminal diagram

Heat recovery ventilators (HRVs) have their own required clearances – for instance, the intake and exhaust need to be located at least six feet from each other.  The HRV shown below has the intake and exhaust with about four feet of separation.

HVAC - HRV clearances

Most HRVs need to be balanced when they’re installed; if there are no screws present to lock the dampers in place, it hasn’t been balanced or someone wasted their time balancing it and it needs to be done again.

HVAC - HRV not balanced

Structure

Most structural problems manifest themselves years down the road from latent defects, but sometimes they’re obvious.  In the photo below, someone took a sizable notch out of one of the beams.  If this was part of the original plans, great… but I’d bet anything it wasn’t.

Framing - notched beam

Remember how I said that the wrong hangers are often used on decks because installers just don’t have the proper hangers with them?  Sometimes this happens inside the house too.

Framing - wrong hanger

This next photo is one of my favorites; someone bent the heck out of this stairway stringer bracket and used it on a floor joist.   Just in case you needed a reminder, this is new construction.  Big, reputable builders.

Framing - torn hanger

Attics

As I’ve said in previous blogs, attics should always be inspected, whether the attic access panel has been ‘sprayed shut’ or not.    In the photo below, the roof vents weren’t properly lined up with the holes in the roof sheathing, which significantly reduces the total amount of attic ventilation.

Attics - bad hole for roof vent

In the next photo, they completely forgot to install a roof vent; I’m glad I didn’t put my foot through.

Attics - missing roof vent

Broken truss chord – I’m guessing too many bundles of shingles were unloaded in one place.  I can’t be too critical of this because I’ve done it myself,  but the big difference for me is that I fixed it after I broke it.

Attics - broken truss chord 2

Same thing, different house.

Attics - Broken truss chord

This photo below shows a disconnected duct from a bathroom exhaust fan; just think about how much moisture would get pumped in to that attic over the years if it never got fixed.

Attics - loose bath fan duct

When truss manufacturers put green stickers on every truss saying “Permanent Lateral Bracing Required”, I expect to see permanent lateral bracing installed.  This new construction house didn’t have any.

Attics - permanent lateral bracing required

Finally, here’s one of my favorites.  I took this photo at a five-year-old townhouse that had two separate attic areas.  One was insulated, one wasn’t.  Wow.

Attics - missing insulation

I have a lot more photos that I could share, but hopefully I’ve made my point; just because a home is new doesn’t mean it’s right.  If you’re buying a home, get a home inspection.  It doesn’t matter if the house is new or not.

Reuben Saltzman, Structure Tech Home Inspections – Email – Minneapolis Home Inspections

Facebook Reuben's LinkedIn Page Follow StructureTech on Twitter ASHI Certified Home Inspector - Click To Verify Click to subscibe to Reuben's Blog

13 responses to “Photos From New Construction Inspections”

  1. Jim Allhiser
    November 2, 2010, 8:04 am

    Holly cow! Great post buddy!
    It is interesting that new homes are some of the WORST homes that I get to look at. I think you spent a while compiling this block of evidence to prove our claims!

  2. Reuben Saltzman
    November 3, 2010, 4:31 am

    Jim – don’t you know it. This did take a while to put together, but it was fun going over all these photos again.

  3. Jordan Schroeder
    November 4, 2010, 12:53 pm

    Great post…..this will be very helpful when I encourage buyers of new constructing to get an inspection.

  4. Reuben Saltzman
    November 4, 2010, 3:41 pm

    Thanks Jordan – if this doesn’t convince someone, I don’t know what would.

  5. garage door san antonio
    November 9, 2010, 4:57 am

    I would not mind hiring a good private home inspector,who could well defined the condition of newly constructed house. I agree with you on the point of seeing the photos.

  6. Pillar To Post
    November 11, 2010, 3:08 pm

    These are great pictures!
    The issue with bypassing a home inspection on newly constructed homes (that comes with a 1 year warranty) is that some of the (more interesting) problems may not surface until well after the 12 month warranty has expired.

  7. Reuben Saltzman
    November 11, 2010, 3:54 pm

    Pillar To Post – exactly. Many of these issues wouldn’t be discovered until a lot of damage had been done.

  8. Are Re-Inspections Necessary? | Structure Tech Home Inspections
    August 16, 2011, 3:51 am

    […] it may still be worthwhile.  Just as we find countless defects by licensed contractors on new construction inspections, improper repairs frequently happen with real estate transactions, no matter who does the work. […]

  9. Ollie M
    January 18, 2012, 4:26 am

    Interesting posts, your new homes only come with a 1 year guarantee?
    In UK 10 years is a legal requirement. As Pillar to Post states, many problems/latent defects will not reveal themselves until well after a year

  10. A New Attic Problem with New Construction Homes | Structure Tech Home Inspections
    March 27, 2012, 3:49 am

    […] been doing a lot of new-construction inspections or one-year warranty inspections on new construction houses, and I’ve started to notice a new […]

  11. Tim S
    September 18, 2012, 7:44 am

    Wow – It sure makes you wonder about the quality / ethics of the city building inspectors!

  12. Peter Haydon
    October 29, 2013, 9:32 pm

    This stuff obviously happens everywhere. I’ve been building in NZ for 40 years and it sickens me to see it over and over. Great blog. More power to you and the Holmes of this world.

  13. Photos from New Construction Home Inspections, Part III | Structure Tech Home Inspections
    December 7, 2013, 6:19 am

    […] Photos From New Construction Home Inspections, part I […]

RSS feed for comments on this post.

Comments on posts over 90 days old are disabled, as of 1/7/14.