Reuben Saltzman

Photos from New Construction Home Inspections, Part II

“New construction homes get inspected dozens of times by municipal inspectors as part of the permit process, so there is no need to hire a private home inspector if you’re buying a new home.”

I hear that a lot.  I do my best to convince home buyers otherwise, but when I’m on the phone with a potential client, I have a financial interest in talking them in to hiring me.  Just like the orthodontist will tell you your kid needs braces, the home inspector is going to say you need a home inspection.

I get it.

That’s why I try to direct people on the phone to my blog; if these photos don’t convince you that a private home inspection is a worthwhile investment on a new construction home, I don’t know what will.  Most of the photos below were taken at new construction homes that have already been through the permit inspection process; in a couple cases, the homes were a year or two old, but the photos show defects that were original to construction.

Roofs

New construction roofs are not impervious to installation defects – the most common issue we find with new roof installations is improper shingle nailing.  When nails are overdriven, driven at an angle, or located too high on the shingles, it’s a defective installation.  The photos below show a few examples of defective roof installations on new construction homes.

Roofs - loose shingles

Roofs - overdriven nails (2)

Roofs - overdriven nails 2

Short nails on a new roof isn’t a common defect, but I’ve found them.  In the photo below, the ridge shingles were fastened with 1-1/4″ nails, which barely even touched the roof sheathing.  I could pull ’em right out by hand.

Roofs - short nails at ridge

Why didn’t the municipal inspectors catch these defects?  Most municipal inspectors don’t walk on roofs.

What happens when these defects are identified?  In extreme cases, the roofers need to start over.  Full tear-off and replacement.  The photo below shows new shingles delivered on top of the existing roof that was only a week or two old.  The home buyer sent me this photo to show that the builder was making good with their defective installation… that had already been approved by the municipal inspector.

Roofs - shingles delivered on new home

Exterior

This deck beam should have been attached to the 6×6 post with a metal bracket; not bumped out over the side of the post and attached to the sliver that was left.

Decks - improper beam attachment at post

The diagram below shows what this would look like if done properly.

Decks - beam attachment diagram

I’ve blogged about improper joist hanger nails before, and it’s still a defect that I find on new construction.

Decks - improper nails at floor joists

The problem with these short nails is that they don’t even begin to penetrate the ledgerboard, as you can clearly see in the photo below.

Decks - short nails at joist hanger labeled

Sometimes the nails in joist hangers get completely missed, especially when it’s the inside corner on a skewed hanger.

Decks - missing nails at joist hangers

Other times, joist hangers are forgotten about entirely.

Decks - missing joist hanger

Masonry veneer (aka stone siding) installation defects are rampant.  I recently blogged about stone siding installation defects, and all of the photos in that blog post came from new construction homes or new installations that were approved with permits.

For example, masonry veneer needs to be kept 2″ above the roof covering.  In the photo below, the mortar was actually touching the shingles, and this was located near the bottom of a valley.  This part of the roof wasn’t visible from the ground, and the municipal inspector had just recently approved the installation.

Stone siding too close to shingles

Other siding manufacturers have similar requirements for clearance to the shingles.  For example, James Hardie requires a 2″ gap between the bottom of the siding and the roof covering.  When these clearance requirements aren’t met, the siding can soak up moisture and flake apart.

Exterior - siding too close to shingles

Sometimes, a private home inspector might point out an area of concern.  When roof lines are designed to direct water against the house, this is a concern.  It’s not necessarily a ‘building code defect’, but it sure isn’t good planning.  I took the photo below at a home that was just two years old, but was already experiencing major water intrusion problems at the area circled in yellow.  The dotted blue line shows the path water was taking inside the wall.

Exterior - roof lines marked up

The photo below shows the water staining that had made its way to the first floor subfloor, and was visible in the basement.

Exterior - roof line flaw and leaking

Auto-reverse sensors on garage door openers need to be installed within 6″ of the floor to help reduce the risk of injuries.

Exterior - auto-reverse sensors improperly located

Since 2007, the minimum tread depth on a stairway has been 10″ in Minnesota.  So how did these steps leading up to the front door pass inspection?

Exterior - improper tread depths

As you can see below, the front porch / deck was over 30″ above the surrounding grade, so guardrails are required.  Of course, this inspection was done in the middle of the winter and the grading wasn’t finished yet, so I let the buyer know that this is something that needs to be followed up on as a safety issue in the spring.  If the finished grade ends up being 29 1/2″ high… is it safe?

Missing Guardrail

HVAC

High-efficiency furnaces and water heaters need to have the venting pitched so water drains out; there should never be any dips in the piping that allow water to pool.  The two photos below show improperly pitched furnace venting.  I added the blue to show where water will pool.

HVAC - backpitched furnace vent

HVAC - backpitched furnace vent 2

This next one was downright scary; the water heater installer forgot to glue one of the joints at the vent, and it worked itself loose.  That would allow for a lot of exhaust gas in to the home.

HVAC - disconnected water heater vent

Allow me to digress for a second.  If this disconnected water heater vent hadn’t been discovered before the buyers moved in, how long would this have gone on for?  It probably wouldn’t generate enough carbon monoxide to kill anyone, but long-term exposure to low levels of carbon monoxide isn’t good, and the excess moisture being dumped in to the home would surely cause moisture problems.  When I find stuff like this, it’s usually a very quick and easy fix for the builder.  If this had been leaking exhaust gases in to the home for years, it could turn in to a nasty lawsuit.

This makes me wonder why so many builders try to talk home buyers out of having private inspections.  This is the home builder’s chance for someone else to look over their work to identify safety issues and building performance issues that might turn in to big problems further on down the road… and the builder doesn’t even pay for the home inspection, the buyer does!  Builders ought to be encouraging buyers to get home inspections.

I find a lot of loose and sloppy HVAC ductwork on new construction inspections.  I removed the register cover to show this loose ductwork.

HVAC - loose ductwork

Toekick register covers are sometimes forgotten about, because you can’t see ’em unless you bend down.  As you can see, this one was skipped.

HVAC - missing register (2)

So was this one.

HVAC - missing register

Sometimes the register covers get missed because the carpet installers hide the registers.  The image below, right, shows an infrared image overlay.  Oops.

Missing floor register 1  Missing floor register

Gaps like this in the ductwork means unwanted air leakage.

HVAC - Unsealed ductwork

When ducts are crushed, air flow is seriously reduced.  I found this crushed duct at a recent pre-drywall inspection.

HVAC - crushed duct

The ground always settles around new houses.  Sometimes, it settles very quickly.  When this happens, air conditioners can tip.

HVAC - tipping air conditioner

When they tip too much, this places stress on the refrigerant lines.  The air conditioner shown below was only two years old, and it was already hanging from the refrigerant lines.

HVAC - settled grade at AC

The photo below shows an anti-tip bracket for a gas range sitting on the floor behind the range.  When I pulled the range forward to make sure the anti-tip bracket was properly installed, I felt it give way.  Someone had simply screwed the bracket in to the drywall.  That doesn’t do much good.

HVAC - improperly installed anti-tip bracket

This was a brand new gas fireplace that was leaking exhaust gas.  This needs to be fixed before the fireplace gets used.

HVAC - leaking exhaust gas at new fireplace

Plumbing

As with the photos of the furnace and water heater vents shown above, plumbing vents and drains need to be pitched so water drains out.  I added the blue in the photo below to show where water will end up sitting.

Plumbing - backpitched vent

When CSST gas lines are used, they need to be properly bonded to reduce the risk of fire from a nearby lightening strike.  This doesn’t always happen.

Plumbing - CSST not bonded

When dishwashers are installed below granite countertops, they’re often not attached because nobody wants to drill holes in the granite.  I’ve probably seen half a dozen ways of attaching the dishwasher without drilling holes in the granite top; I’ll have to start taking pictures of those methods and follow up with a blog post on this topic alone.

Plumbing - loose dishwasher

Brand new dishwasher installations usually work fine, but not always.  This dishwasher leaked like crazy.  I was inspecting the basement when the leaking started, so I was able to run upstairs and turn it off immediately, but a lot of water had already leaked underneath the cabinets and in to the subfloor in the kitchen.

Of course, this is one of those things that the builder would unquestionably fix, but far better I find it than the homeowner.  Can you imagine what a mess this would have been if the new homeowner had already moved in and the dishwasher leaked in to the basement all over their stuff for a full cycle?

Plumbing - leaking dishwasher

When there is an access panel present for the bath tub drain, I usually inspect the bath tub by filling up the tub to the overflow, and then observe the overflow from the access panel to make sure it isn’t leaking.

Unless, of course, the access panel doesn’t really give access.  I have dozens of photos just like this one.

Plumbing - missing access hole

Every gas appliance needs to have a union, or some method of disconnecting the gas piping after shut shutoff valve.  It obviously doesn’t do much good to have the union installed before the shutoff valve.  This is a detail that occasionally gets forgotten about on water heaters.  Even on new construction.

Plumbing - missing union

After the drain, waste, and vent system has been tested, the test caps on the vents at the roof need to be removed.  About 10% of the time, they get forgotten about.  This effectively disables the vents.

Plumbing vent cap not removed

Electrical

I don’t find a lot of electrical defects on new construction homes.  This is the one trade where the installations are almost always very clean… almost.    In the photo below, there are two neutral conductors connected to a single terminal.  Each neutral conductor needs to be connected to its own terminal.

Electrical - doubled neutrals

Smoke alarm manufacturers require smoke alarms to be installed at least 4″ down from the ceiling when mounted on a wall, measured from the top edge of the smoke alarm.

Electrical - improper smoke alarm location

Structure

This is a new construction home.  It looks like the plumber decided to cut a big chunk of the floor joist out so the toilet could go where he or she wanted it.  The top chords of these floor joists aren’t supposed to be cut out or notched.

Structure - cut floor joist

Attics

It’s very rare that we don’t ‘break the seal‘ at the attic access panel in order the inspect the attic.  This is an important part of every home inspection, even in new construction.  I broke the attic access seal on a new construction home about two weeks ago and found the light was left on in the attic.

Attic - light on

Just because the insulation installer left a placard in the attic stating the insulation depth, it doesn’t mean they followed through.  It should, but it doesn’t.  Some areas of the attic pictured below had nearly less than half of the minimum required amount of insulation.

Attic - insulation placard 2

Attic - improper insulation depth

Fiberglass batts do a terrible job of insulating attics because they’re impossible to install properly – they end up leaving gaps all over the place.  In the middle of the photo below, the insulation was compressed down to 3-1/2″ thick, which is completely inadequate.  This is new construction!

Attic - Improperly installed fiberglass batts

When data tubes end in the attic, the ends need to be sealed off to help prevent them from pumping conditioned air in to the attic like a chimney.

Attic - open data tube

Conclusion

I could go on and on with these photos, but hopefully I’ve made my point.  If you’re buying a new construction home, hire a private home inspector.  If you recently purchased a new construction home and you’re still within your one-year warranty period, hire a home inspector.

Related Posts:

Reuben Saltzman, Structure Tech Home Inspections

        

13 responses to “Photos from New Construction Home Inspections, Part II”

  1. Ben
    September 18, 2012, 5:20 am

    Preach the good word Reuben. Why people actually trust the government to protect them when spending hundreds of thousands of dollars is beyond me.

  2. Property Inspection
    October 11, 2012, 11:32 am

    Its a very useful article, I think people must read it if they are going to build a home.

  3. House Inspection
    November 2, 2012, 7:31 am

    Most valuable post,I will appreciate that.
    Photos are really awesome to convincing people on it.

  4. BK
    November 5, 2012, 10:02 am

    Is the smoke detector requirement for new homes only? Our house has all of them mounted on the ceiling.

  5. Reuben Saltzman
    November 5, 2012, 11:53 am

    Hi BK,

    I just had someone else send me a similar email – I guess my wording wasn’t very clear. The preferred location for a smoke alarm is actually on the ceiling, in the middle of the room. If a smoke alarm gets mounted on a wall, however, it needs to be at least 4″ down from the ceiling. I just changed the wording in this post to make this a little more clear.

  6. sean ahner
    November 16, 2012, 3:37 am

    This blog is very useful! I suggest if you will build a house you must visit first this blog to have a good idea about building a new house.

  7. Chris
    January 5, 2013, 12:29 pm

    You show a picture of a crushed air duct, Then you show a picture of a cut floor joist which you cant do. You cant cut though a micro lamb beam and you cant cut a floor joist. That was most likely the only place to run that duct work. Do to were they had to install furnace . That would be why they used the flex ducting to slid though gap in micro lamb and the floor joist because there is no place else to run it. That is very common.

  8. Paul Inman
    February 12, 2013, 12:37 am

    I pretty much agree with all your pictures of building flaws, but the one that you claim the joist was cut to short on the treated deck cracks me up. You OBVIOUSLY have never built a deck with NEW treated lumber. When this lumber comes from the yard it is 3 to 4 times the weight of its Kiln dried same size dimension lumber counterpart. When this lumber dries out because of the sun and wind it SHRINKS. DUHH Home inspectors don’t know everything.

  9. Reuben Saltzman
    February 12, 2013, 4:55 am

    Hi Paul,

    What photo are you referring to? Are you looking at the photo of the joist hanger nails that are too short, with the text above that says “The problem with these short nails is that they don’t even begin to penetrate the ledgerboard, as you can clearly see in the photo below.” ? Please, do get back to me.

  10. Who Inspected Your Attic? | Structure Tech Home Inspections
    February 26, 2013, 5:20 am

    […] two recent new construction inspections in Plymouth, we received notice from the builders giving us explicit instructions NOT to open the […]

  11. LaRay W
    July 7, 2013, 3:23 pm

    I am having a new home build and close at the end of this month. I’m having major concerns on he quality of the work being done. Such as a huge crack in the middle of the slab the expands the whole home in the form of the letter “T”. I have pictures, Is there someone I can send them to see If someone can tell me if I have to worry about anything. I’m having a nightmare with a builder that are blowing my concerns to the side and covering up as hey Go. What do I Do?

  12. Dominic
    September 25, 2013, 1:47 pm

    Run away LaRay!!! Run away!

  13. Photos from New Construction Home Inspections, Part III | Structure Tech Home Inspections
    November 17, 2013, 2:50 pm

    […] Photos From New Construction Home Inspections, part II […]

RSS feed for comments on this post.

Comments on posts over 90 days old are disabled, as of 1/7/14.